Abstract & Details
Description
Award ID: 2324768
The broader impact/commercial potential of this I-Corps project is the development of an optical sensor that measures calories burned in real time. The proposed technology addresses the need for physicians and dieticians to accurately map a patients metabolic rate, which may provide information to assist in guiding proper nutrition and significantly reduce costs in seriously ill patients. In addition, professional athletes and others in the fitness industry may utilize such a technology to further develop and track their performance, providing crucial information to their coaches and sports medicine personnel. Current standard technologies, such as the metabolic cart, are large, cost-prohibitive (>$50K), and require intensive training and personnel for operation. As an inexpensive alternative, clinicians rely on crude calculations and daily weight measurements to guide patient nutrition. These predictive equations are often not accurate and are non-inclusive, only applying to a subset of the population. Dietitians struggle with making estimates for a variety of patients, especially for premature infants and patients that are obese, undergoing liver transplant surgeries, or suffering from thyroid problems. Accurate metabolic information from the proposed device may significantly increase quality of care, reduce readmission rates, length of stay, and complications, and contribute to reduced costs and positive healthcare outcomes. This I-Corps project is based on the development of an optical sensor that evaluates peculiar gas analyte concentrations in the bloodstream to quantify the end-users metabolic rate. The goal is to implement the metabolism sensor as a wearable device to measure calorie output from a patients extremity (finger or ear). The metabolic rate sensor utilizes a transdermal or transcutaneous, non-invasive optical sensor that measures carbon dioxide (CO2) and oxygen (O2) levels in the blood. The ratio of incident light to collected light through tissue will provide the data needed to calculate the patients energy expenditure. As caloric fuel is burned in the body in the presence of O2, CO2 is produced before being exhaled. The sensor system employs low-cost light emitting diodes (LEDs) and photodiodes to measure the absorption and scattering of light at wavelengths specific to spectral markers of O2 and CO2. A proprietary algorithm adopted from the Weir equation estimates the number of calories burned in real time from continuous spectral measurement. This award reflects NSF's statutory mission and has been deemed worthy of support through evaluation using the Foundation's intellectual merit and broader impacts review criteria.
NSF Program Director: Molly Wasko
The broader impact/commercial potential of this I-Corps project is the development of an optical sensor that measures calories burned in real time. The proposed technology addresses the need for physicians and dieticians to accurately map a patients metabolic rate, which may provide information to assist in guiding proper nutrition and significantly reduce costs in seriously ill patients. In addition, professional athletes and others in the fitness industry may utilize such a technology to further develop and track their performance, providing crucial information to their coaches and sports medicine personnel. Current standard technologies, such as the metabolic cart, are large, cost-prohibitive (>$50K), and require intensive training and personnel for operation. As an inexpensive alternative, clinicians rely on crude calculations and daily weight measurements to guide patient nutrition. These predictive equations are often not accurate and are non-inclusive, only applying to a subset of the population. Dietitians struggle with making estimates for a variety of patients, especially for premature infants and patients that are obese, undergoing liver transplant surgeries, or suffering from thyroid problems. Accurate metabolic information from the proposed device may significantly increase quality of care, reduce readmission rates, length of stay, and complications, and contribute to reduced costs and positive healthcare outcomes. This I-Corps project is based on the development of an optical sensor that evaluates peculiar gas analyte concentrations in the bloodstream to quantify the end-users metabolic rate. The goal is to implement the metabolism sensor as a wearable device to measure calorie output from a patients extremity (finger or ear). The metabolic rate sensor utilizes a transdermal or transcutaneous, non-invasive optical sensor that measures carbon dioxide (CO2) and oxygen (O2) levels in the blood. The ratio of incident light to collected light through tissue will provide the data needed to calculate the patients energy expenditure. As caloric fuel is burned in the body in the presence of O2, CO2 is produced before being exhaled. The sensor system employs low-cost light emitting diodes (LEDs) and photodiodes to measure the absorption and scattering of light at wavelengths specific to spectral markers of O2 and CO2. A proprietary algorithm adopted from the Weir equation estimates the number of calories burned in real time from continuous spectral measurement. This award reflects NSF's statutory mission and has been deemed worthy of support through evaluation using the Foundation's intellectual merit and broader impacts review criteria.
NSF Program Director: Molly Wasko
| Status | Closed |
|---|---|
| Effective start/end date | 06/01/23 → 05/31/24 |
Funding
- I-Corps Teams: $50,000.00
Active Fiscal Year
- FY2024
- FY2023
Start Fiscal Year
- FY2023
TIP Programs
- I-Corps Teams
Key Technology Areas
- Biotechnology
- (confidence score: 100%)
Technology Foci
- Medical Technology
- (confidence score: 99%)
Congressional District at Award
- District n. 05 of Tennessee
Current Congressional District
- District n. 07 of Tennessee
United States
- Tennessee
Core Based Statistical Area (CBSA)
- Nashville-Davidson--Murfreesboro--Franklin, TN
County
- County: Davidson, TN
Fingerprint
Explore the research topics touched on by this project. These labels are generated based on the underlying awards/grants. Together they form a unique fingerprint. Learn more about Elsevier's Fingerprint Engine here: https://beta.elsevier.com/products/elsevier-fingerprint-engine