Abstract & Details
Description
Award ID: 2528273
The broader impact / commercial potential of this Small Business Innovation Research (SBIR) Phase I project is to potentially improve the accuracy, consistency, and efficiency of prostate cancer diagnosis using magnetic resonance imaging (MRI). Today, MRI scans used in prostate cancer screening can vary significantly depending on the machine and manufacturer, which makes it challenging for radiologists and software to provide consistent assessments. This project aims to create a software system that standardizes these images and provides accurate, editable 3D outlines of the prostate to support diagnostic decisions. The technology will help ensure that patients, regardless of where or how they are scanned, receive the same high-quality analysis. By reducing unnecessary imaging, streamlining radiologist workflows, and enabling more consistent evaluations, this innovation has the potential to improve early detection and reduce disparities in care. If successful, the solution will become an essential part of the prostate imaging workflow, supporting a variety of downstream clinical tools and improving access to equitable and efficient prostate cancer care. This Small Business Innovation Research (SBIR) Phase I project will develop a style-encoding generative adversarial network (GAN) to harmonize prostate MRI images from different scanner vendors and field strengths while preserving anatomical detail. A transformer-based UNETR segmentation model will then produce precise binary masks of the prostate and voxel-level uncertainty maps. The architecture includes a segmentation-aware loss function that ensures harmonized images maintain diagnostic utility when passed through a frozen segmentation model. Phase I will evaluate this pipeline using a diverse, multi-vendor prostate MRI dataset. Key performance indicators will include segmentation accuracy using the Dice similarity coefficient and Hausdorff distance, anatomical fidelity measured by structural similarity (SSIM), and radiologist editing time. Successful completion of this project will establish the technical feasibility of a scanner-agnostic, confidence-aware segmentation tool capable of supporting real-time, human-in-the-loop clinical workflows. This award reflects NSF's statutory mission and has been deemed worthy of support through evaluation using the Foundation's intellectual merit and broader impacts review criteria.
NSF Program Director: Alastair Monk
The broader impact / commercial potential of this Small Business Innovation Research (SBIR) Phase I project is to potentially improve the accuracy, consistency, and efficiency of prostate cancer diagnosis using magnetic resonance imaging (MRI). Today, MRI scans used in prostate cancer screening can vary significantly depending on the machine and manufacturer, which makes it challenging for radiologists and software to provide consistent assessments. This project aims to create a software system that standardizes these images and provides accurate, editable 3D outlines of the prostate to support diagnostic decisions. The technology will help ensure that patients, regardless of where or how they are scanned, receive the same high-quality analysis. By reducing unnecessary imaging, streamlining radiologist workflows, and enabling more consistent evaluations, this innovation has the potential to improve early detection and reduce disparities in care. If successful, the solution will become an essential part of the prostate imaging workflow, supporting a variety of downstream clinical tools and improving access to equitable and efficient prostate cancer care. This Small Business Innovation Research (SBIR) Phase I project will develop a style-encoding generative adversarial network (GAN) to harmonize prostate MRI images from different scanner vendors and field strengths while preserving anatomical detail. A transformer-based UNETR segmentation model will then produce precise binary masks of the prostate and voxel-level uncertainty maps. The architecture includes a segmentation-aware loss function that ensures harmonized images maintain diagnostic utility when passed through a frozen segmentation model. Phase I will evaluate this pipeline using a diverse, multi-vendor prostate MRI dataset. Key performance indicators will include segmentation accuracy using the Dice similarity coefficient and Hausdorff distance, anatomical fidelity measured by structural similarity (SSIM), and radiologist editing time. Successful completion of this project will establish the technical feasibility of a scanner-agnostic, confidence-aware segmentation tool capable of supporting real-time, human-in-the-loop clinical workflows. This award reflects NSF's statutory mission and has been deemed worthy of support through evaluation using the Foundation's intellectual merit and broader impacts review criteria.
NSF Program Director: Alastair Monk
| Status | Closed |
|---|---|
| Effective start/end date | 07/15/25 → 04/30/26 |
Lead and Sub-Awardee Organization(s)
Funding
- SBIR Phase I: $305,000.00
Active Fiscal Year
- FY2026
- FY2025
Start Fiscal Year
- FY2025
TIP Programs
- SBIR Phase I
Small Business
- Yes
Key Technology Areas
- Super Intelligence
- (confidence score: 98%)
- Biotechnology
- (confidence score: 99%)
Technology Foci
- Medical Technology
- (confidence score: 100%)
- Super Intelligence (Broad)
- (confidence score: 100%)
Congressional District at Award
- District n. 25 of New York
Current Congressional District
- District n. 25 of New York
United States
- New York
Core Based Statistical Area (CBSA)
- Rochester, NY
County
- County: Monroe, NY
Fingerprint
Explore the research topics touched on by this project. These labels are generated based on the underlying awards/grants. Together they form a unique fingerprint. Learn more about Elsevier's Fingerprint Engine here: https://beta.elsevier.com/products/elsevier-fingerprint-engine